Clinical Rehabilitation

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simpson, J. M
Right arrow Articles by Worsfold, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simpson, J. M
Right arrow Articles by Worsfold, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Clinical Rehabilitation, Vol. 16, No. 8, 843-850 (2002)
DOI: 10.1191/0269215502cr569oa

The Standardized Three-metre Walking Test for elderly people (WALK3m): repeatability and real change

Janet M Simpson

Department of Geriatric Medicine, St George's Hospital Medical School, London, UK

John Valentine

Department of Psychology Royal Holloway, University of London, London, UK

Christian Worsfold

Department of Geriatric Medicine, St George's Hospital Medical School, London, UK

Objectives: (i) To examine the relative and absolute retest within-session reliability of the Standardized Three-metre Walking Test for elderly people (WALK3m), using walking time and number of steps as measures. (ii) To give clinicians details of how they can use the minimal detectable change in order to decide whether a patient's WALK3m performance has really changed. (iii) To give rules to decide whether one trial rather than three is sufficient.

Design and analysis: Subjects made three trials of WALK3m in the same session. Variability and level of performance were related so the data were log (ln) transformed. Relative reliability was measured by the intraclass correlation coefficient (ICC) then absolute reliability by the repeatability factor (RF) and minimal detectable change (MDC) (one-tailed and two-tailed) was derived from the within-subjects standard deviation.

Setting: Rehabilitation areas in the acute geriatric medical units at three south-west London hospitals.

Subjects: The standardizing sample consisted of 81 inpatients approaching discharge to their own homes.

Results: The ICC for walking time was 0.97 and for step counts 0.96. The MDC for walking is a 36% decrease between first and second measurements. The corresponding value for step counts is 21%.

Conclusion: WALK3m, whether measured by time or by step counts has excellent repeatability. Knowing the minimal detectable change can be of great value to clinicians who can calculate whether their patient is really making progress.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Clin RehabilHome page
A. Linder, L. Winkvist, L. Nilsson, and N. Sernert
Evaluation of the Swedish version of the Modified Elderly Mobility Scale (Swe M-EMS) in patients with acute stroke
Clinical Rehabilitation, July 1, 2006; 20(7): 584 - 597.
[Abstract] [PDF]


Home page
Clin RehabilHome page
C Fitzpatrick, J M Simpson, J D Valentine, S Ryder, T Peacock-Edwards, P Sidnell, and M Colognese
The measurement properties and performance characteristics among older people of TURN180, a test of dynamic postural stability
Clinical Rehabilitation, April 1, 2005; 19(4): 412 - 418.
[Abstract] [PDF]


Home page
Clin RehabilHome page
J. Valentine and J. M Simpson
Deciding whether a change in a patient's performance is a genuine change
Clinical Rehabilitation, August 1, 2002; 16(8): 837 - 842.
[Abstract] [PDF]