SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Clinical Rehabilitation
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Lamb, S.
Right arrow Articles by Mani, R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lamb, S.
Right arrow Articles by Mani, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Does intereferential therapy affect blood flow?

Sarah Lamb

Department of Rehabilitation Studies Southampton General Hospital

Raj Mani

Department of Medical Physics, Southampton General Hospital, Southampton

Interferential therapy (IT) is an electrothrapeutic technique widely used in physiotherapy departments to treat pain and soft-tissue injuries. It has been suggested that IT has a dose-related effect on blood flow, and as such, can be used in the management of a variety of circulatory disorders. There is no satisfactory evidence to support these claims. The aim of this study was to establish noninvasive methods of measuring the response of the arterial and microcirculation concomitantly; and to document the circulatory response in the adult human volunteer. Three frequencies of IT were tested (0-30 Hz, 45-90 Hz and 100-150 Hz). The results suggest that IT currents can be used to increase arterial and microcirculatory blood flow; and that the response is dose-related.

Clinical Rehabilitation, Vol. 8, No. 3, 213-218 (1994)
DOI: 10.1177/026921559400800305


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




Advertisement