Clinical Rehabilitation

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rankin, G.
Right arrow Articles by Stokes, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Rankin, G.
Right arrow Articles by Stokes, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Clinical Rehabilitation, Vol. 12, No. 3, 187-199 (1998)
DOI: 10.1191/026921598672178340
© 1998 SAGE Publications

Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses

Gabrielle Rankin

Maria Stokes

Royal Hospital for Neuro-disability, London

Objective: To provide a practical guide to appropriate statistical analysis of a reliability study using real-time ultrasound for measuring muscle size as an example.

Design: Inter-rater and intra-rater (between-scans and between-days) reliability.

Subjects: Ten normal subjects (five male) aged 22–58 years.

Method: The cross-sectional area (CSA) of the anterior tibial muscle group was measured using real-time ultrasonography.

Main outcome measures: Intraclass correlation coefficients (ICCs) and the 95% confidence interval (CI) for the ICCs, and Bland and Altman method for assessing agreement, which includes calculation of the mean difference between measures (d), the 95% CI for d, the standard deviation of the differences (SD diff), the 95% limits of agreement and a reliability coefficient.

Results: Inter-rater reliability was high, ICC (3,1) was 0.92 with a 95% CI of 0.72 -> 0.98. There was reasonable agreement between measures on the Bland and Altman test, as d was -0.63 cm2, the 95% CI for d was -1.4 -> 0.14 cm2, the SDdiff was 1.08 cm2, the 95% limits of agreement -2.73 -> 1.53 cm2 and the reliability coefficient was 2.4. Between-scans repeatability was high, ICCs (1,1) were 0.94 and 0.93 with 95% CIs of 0.8 -> 0.99 and 0.75 -> 0.98, for days 1 and 2 respectively. Measures showed good agreement on the Bland and Altman test: d for day 1 was 0.15 cm2 and for day 2 it was -0.32 cm2, the 95% CIs for d were -0.51 -> 0.81 cm2 for day 1 and -0.98 -> 0.34 cm2 for day 2; SDdiff was 0.93 cm2 for both days, the 95% limits of agreement were -1.71 -> 2.01 cm2 for day 1 and -2.18 -> 1.54 cm2for day 2; the reliability coefficient was 1.80 for day 1 and 1.88 for day 2. The between-days ICC (1,2) was 0.92 and the 95% CI 0.69 0.98. The d was -0.98 cm2, the SDdiff was 1.25 cm2 with 95% limits of agreement of -3.48 -> 1.52 cm2 and the reliability coefficient 2.8. The 95% CI for d(-1.88 -> -0.08 cm2) and the distribution graph showed a bias towards a larger measurement on day 2.

Conclusions: The ICC and Bland and Altman tests are appropriate for analysis of reliability studies of similar design to that described, but neither test alone provides sufficient information and it is recommended that both are used.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
ptjournalHome page
J. M Wagner, J. A Rhodes, and C. Patten
Reproducibility and Minimal Detectable Change of Three-Dimensional Kinematic Analysis of Reaching Tasks in People With Hemiparesis After Stroke
Physical Therapy, May 1, 2008; 88(5): 652 - 663.
[Abstract] [Full Text] [PDF]


Home page
J. Gerontol. A Biol. Sci. Med. Sci.Home page
J. F. Signorile, D. Sandler, L. Kempner, D. Stanziano, F. Ma, and B. A. Roos
The Ramp Power Test: A Power Assessment During a Functional Task for Older Individuals
J. Gerontol. A Biol. Sci. Med. Sci., November 1, 2007; 62(11): 1266 - 1273.
[Abstract] [Full Text] [PDF]


Home page
ptjournalHome page
M. Conradsson, L. Lundin-Olsson, N. Lindelof, H. Littbrand, L. Malmqvist, Y. Gustafson, and E. Rosendahl
Berg Balance Scale: Intrarater Test-Retest Reliability Among Older People Dependent in Activities of Daily Living and Living in Residential Care Facilities
Physical Therapy, September 1, 2007; 87(9): 1155 - 1163.
[Abstract] [Full Text] [PDF]


Home page
Neurorehabil Neural RepairHome page
H.-M. Chen, C.-L. Hsieh, Sing Kai Lo, L.-J. Liaw, S.-M. Chen, and J.-H. Lin
The Test-Retest Reliability of 2 Mobility Performance Tests in Patients With Chronic Stroke
Neurorehabil Neural Repair, July 1, 2007; 21(4): 347 - 352.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. El-Ansary, G. Waddington, and R. Adams
Measurement of Non-Physiological Movement in Sternal Instability by Ultrasound
Ann. Thorac. Surg., April 1, 2007; 83(4): 1513 - 1516.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Sports. Med.Home page
P M Grant, C G Ryan, W W Tigbe, and M H Granat
The validation of a novel activity monitor in the measurement of posture and motion during everyday activities
Br. J. Sports Med., December 1, 2006; 40(12): 992 - 997.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
R. J. Smeets, H. J. Hijdra, A. D. Kester, M. W. Hitters, and J A. Knottnerus
The usability of six physical performance tasks in a rehabilitation population with chronic low back pain.
Clinical Rehabilitation, November 1, 2006; 20(11): 989 - 997.
[Abstract] [PDF]


Home page
ptjournalHome page
G. Verheyden, G. Nuyens, A. Nieuwboer, P. Van Asch, P. Ketelaer, and W. De Weerdt
Reliability and Validity of Trunk Assessment for People With Multiple Sclerosis
Physical Therapy, January 1, 2006; 86(1): 66 - 76.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
C. M Sackley, H. J Hill, K. Pound, and A. Foxall
The intra-rater reliability of the Balance Performance Monitor when measuring sitting symmetry and weight-shift activity after stroke in a community setting
Clinical Rehabilitation, July 1, 2005; 19(7): 746 - 750.
[Abstract] [PDF]


Home page
ptjournalHome page
A B. Deathe and W. C Miller
The L Test of Functional Mobility: Measurement Properties of a Modified Version of the Timed "Up & Go" Test Designed for People With Lower-Limb Amputations
Physical Therapy, July 1, 2005; 85(7): 626 - 635.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
U.-B. Flansbjer, A. M. Holmback, D. Downham, and J. Lexell
What change in isokinetic knee muscle strength can be detected in men and women with hemiparesis after stroke?
Clinical Rehabilitation, May 1, 2005; 19(5): 514 - 522.
[Abstract] [PDF]


Home page
Mult SclerHome page
D Kos, E Kerckhofs, I Carrea, R Verza, M Ramos, and J Jansa
Evaluation of the Modified Fatigue Impact Scale in four different European countries
Multiple Sclerosis, February 1, 2005; 11(1): 76 - 80.
[Abstract] [PDF]


Home page
J. Gerontol. A Biol. Sci. Med. Sci.Home page
T. B. Symons, A. A. Vandervoort, C. L. Rice, T. J. Overend, and G. D. Marsh
Reliability of a Single-Session Isokinetic and Isometric Strength Measurement Protocol in Older Men
J. Gerontol. A Biol. Sci. Med. Sci., January 1, 2005; 60(1): 114 - 119.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
W C Miller, A B Deathe, and J Harris
Measurement properties of the Frenchay Activities Index among individuals with a lower limb amputation
Clinical Rehabilitation, April 1, 2004; 18(4): 414 - 422.
[Abstract] [PDF]


Home page
Br. J. Sports. Med.Home page
K A P M Lemmink, M T Elferink-Gemser, and C Visscher
Evaluation of the reliability of two field hockey specific sprint and dribble tests in young field hockey players
Br. J. Sports Med., April 1, 2004; 38(2): 138 - 142.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
E. Eek and M. Engardt
Assessment of the perceptual threshold of touch (PTT) with high-frequency transcutaneous electric nerve stimulation (Hf/TENS) in elderly patients with stroke: a reliability study
Clinical Rehabilitation, August 1, 2003; 17(8): 825 - 834.
[Abstract] [PDF]


Home page
Clin RehabilHome page
J. M Simpson, J. Valentine, and C. Worsfold
The Standardized Three-metre Walking Test for elderly people (WALK3m): repeatability and real change
Clinical Rehabilitation, August 1, 2002; 16(8): 843 - 850.
[Abstract] [PDF]


Home page
Clin RehabilHome page
F. A Arnall, G. A Koumantakis, J. A Oldham, and R. G Cooper
Between-days reliability of electromyographic measures of paraspinal muscle fatigue at 40, 50 and 60% levels of maximal voluntary contractile force
Clinical Rehabilitation, July 1, 2002; 16(7): 761 - 771.
[Abstract] [PDF]


Home page
Clin RehabilHome page
J. Green, A. Forster, and J. Young
Reliability of gait speed measured by a timed walking test in patients one year after stroke
Clinical Rehabilitation, March 1, 2002; 16(3): 306 - 314.
[Abstract] [PDF]


Home page
Clin RehabilHome page
M A J E Biemans, J Dekker, and L H V van der Woude
The internal consistency and validity of the Self-assessment Parkinson's Disease Disability Scale
Clinical Rehabilitation, February 1, 2001; 15(2): 221 - 228.
[Abstract] [PDF]


Home page
Br. J. Sports. Med.Home page
J. P Buckley, R. G Eston, and J. Sim
Ratings of perceived exertion in braille: validity and reliability in production mode
Br. J. Sports Med., August 1, 2000; 34(4): 297 - 302.
[Abstract] [Full Text] [PDF]


Home page
Clin RehabilHome page
J. M Spyers-Ashby and M. J Stokes
Reliability of tremor measurements using a multidimensional electromagnetic sensor system
Clinical Rehabilitation, April 1, 2000; 14(4): 425 - 432.
[Abstract] [PDF]